NRAO Home  >  Green Bank  |  Wiki Topic:    GB > Operate > LockoutTagoutForLowerManlift (r1.1 vs. r1.4)
   Changes | Index | Contents | Search | Go
 <<O>>  Difference Topic LockoutTagoutForLowerManlift (r1.4 - 06 Feb 2008 - DavidRose)
Changed:
<
<

-- KevinGum - 15 Nov 2004

>
>

-- KevinGum - 6 Feb 2008


 <<O>>  Difference Topic LockoutTagoutForLowerManlift (r1.3 - 17 Nov 2004 - DavidRose)
Deleted:
<
<

-- KevinGum - 15 Nov 2004

Changed:
<
<

The Lockout/Tagout is designed to completely disable the lower manlift or manlift 1 from moving. The Lockout/Tagout will be used when service is required for repairs.

>
>

The Lockout/Tagout procedure is designed to completely disable the lower manlift (manlift 1) from moving. Lockout/Tagout will be used when servicing is required or for repairs.

Deleted:
<
<

Changed:
<
<

3 A lock will be placed through the handle to prevent the handle from being moved or turned back on. With the lock will be a tag expalining who is working on the manlift and the reason why.
>
>

3 A lock will be placed through the handle to prevent the handle from being moved or turned back on. Include with the lock a tag expalining who is working on the manlift and why.

-- KevinGum - 15 Nov 2004


 <<O>>  Difference Topic LockoutTagoutForLowerManlift (r1.2 - 17 Nov 2004 - KevinGum)
Deleted:
<
<

Changed:
<
<

The Lockout/Tagoutis designed to completely disable the lower manlift from moving. The Lockout/Tagout will be used when service is required for repairs.

>
>

The Lockout/Tagout is designed to completely disable the lower manlift or manlift 1 from moving. The Lockout/Tagout will be used when service is required for repairs.

Changed:
<
<

1 Turn off the 480 volt breaker. This breaker is located at the 1st level of the antenna in front of the lower manlift. The breaker is clearly marked, 480 volts.
>
>

1 Turn off manlift #1 480 volt breaker. This breaker is located at the 1st level of the antenna in front of the lower manlift. The breaker is clearly marked, 480 volts.

 <<O>>  Difference Topic LockoutTagoutForLowerManlift (r1.1 - 15 Nov 2004 - KevinGum)
Added:
>
>

%META:TOPICINFO{author="KevinGum" date="1100553243" format="1.0" version="1.1"}% %META:TOPICPARENT{name="TelescopeOperations"}%

-- KevinGum - 15 Nov 2004

TELESCOPE OPERATIONS


Lockout/Tagout for Lower Manlift

General

The Lockout/Tagoutis designed to completely disable the lower manlift from moving. The Lockout/Tagout will be used when service is required for repairs.

STEP ACTION
1 Turn off the 480 volt breaker. This breaker is located at the 1st level of the antenna in front of the lower manlift. The breaker is clearly marked, 480 volts.
2 Pull the handle down. There is only one handle on this box and it will say, " Service Disconnect ". This will cut off all power to the manlift.
3 A lock will be placed through the handle to prevent the handle from being moved or turned back on. With the lock will be a tag expalining who is working on the manlift and the reason why.

Topic LockoutTagoutForLowerManlift . { View | Diffs | r1.4 | > | r1.3 | > | r1.2 | More }