The following are basic procedures used to prepare for pulsar observations using the BCPM.

>
>

The following are basic procedures used in relation to pulsar observations using the BCPM.

Deleted:
<
<

GO (or GO_LITE)

STEP ACTION
NOTE Only one session of GO may be run at any time.
1 To initiate GO with all devices enter: GO (Launches GO with the main menu appearing)
2 To initiate GO with specific devices deselected enter: GO ^ T The GO device menu will appear. Deselect those devices not required.
NOTE If GO hangs while initiating the antenna, start it using this command: GO ^ F ^ 10

Launch CLEO Device Screens

STEP ACTION
1 From the Cleo Launch menu, launch the following application: Applicable Receiver, LO, IF Rack, Converter Rack
2 Launch additional applications if needed or required for the specific observing run.
Changed:
<
<

-- DavidRose - 17 May 2005

>
>

-- DavidRose - 16 Mar 2007


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.6 - 17 May 2005 - DavidRose)
Added:
>
>

General

The following are basic procedures used to prepare for pulsar observations using the BCPM.

Info

Changed:
<
<

General

The following are basic procedures used to prepare for pulsar observations using the BCPM.

Info 

Additional specific settings will be required depending on the observers desires. The following guide shows the basic tasks that may be required:

The character " ^ " is used below to emphasize spaces between dialog elements.

Starting Applications

BCPM Screens    

STEP

ACTION
1 From an xterm window:
  • ssh ^ sadira  (logs in secure to this workstation. You can login to a different workstation if directed)
  • ssh ^ -l ^ bcpm2 ^ bcpm2  (logs in to BCPM and brings up task selection menu) 
  • From the task selection menu, select the u option (user interface) 
  • When prompted for a login name, press enter (default option)

The following windows will launch:

  • Status Display
  • Command Line Interface
  • Graphical User Interface
  • Level Monitor

BCPM Command Line Interface Window Commands

COMMAND

ACTION
setpower Runs a script on the BCPM to set the power levels in the channels.
timing Used to set up the BCPM in timing mode and start acquiring data.
monitor Sets up the BCPM (for search and voltage sampling modes) and acquires data without saving it to disk or tape.
takedata Used in search and voltage sampling modes to commence taking a stretch of search data to disk or tape.
abort Stops the BCPM without saving the last data sample to disk or tape.
stop Stops the BCPM and saves the last data sample to disk or tape.

GO

Info 

GO does not tolerate mutiple iterations of itselfe. Do NOT start GO unless instructed to do so by the observer.

STEP

ACTION
1 To initiate GO with all devices enter:    GO  (Launches GO with the main menu appearing)
2 To initiate GO with specific devices deselected enter:    GO ^ T 

The GO device menu will appear. Deselect those devices not required.

NOTE If GO hangs up while initiating the antenna, start it using this command instead:    GO ^ F ^ 10 

Launch CLEO Device Screens

STEP

ACTION
1 From the Cleo Launch menu, launch the following application:
  • Applicable Receiver
  • LO
  • IF Rack
  • Converter Rack

Launch additional applications if needed or required for the specific observing run.

BCPM GO Panel

Info 

As of 18JAN05 most all setups are done using the config tool. Do not run this unless instructed to by the observer.

STEP

ACTION
1 From an xterm window:    
  • PSRGUI (launches the BCPM GO Panel)

Running The Setup Script

Info 

As of 18JAN05 most all setups are done using the config tool. Do not run this unless instructed to by the observer. Config scripts are no longer supported and may be partially non-functional.

STEP

ACTION
1 From an xterm window:
  • cd ^ include (changes to the include directory)
  • glish ^ -l ^ xxxx.g (substitute the "xxxx" with the applicable script name)
  • Select the option number corresponding to the desired receiver.
  • Select the BCPM (option 1)
  • Enter r (run option)

The BCPM should be ready now.   

Checking IF Power

STEP

ACTION
1 Cleo receiver:
  • Check LO power:  5v is optimal
  • Check noise source:  Firing  
2 Cleo LO
  • Confirm:  LO set for correct signal path to receiver
  • Confirm:  Correct rest frequency
3 Cleo IF Rack:
  • Confirm:  Correct signal path setup for receiver
  • Balance:   IR rack
  • Check RF power:  1v is optimal
4 Cleo Converter Rack:
  • Confirm:  Routing to correct Converter Module (Rack A CM4 & 8)
  • Confirm:  Correct LO2 frequency
  • Check RF power:  Values normally well below 1v
>
>

Additional specific settings will be required depending on the observers desires. The following guide shows the basic tasks that may be required.

  • The character ^ is used below to emphasize spaces between dialog elements.

Starting Applications

BCPM Screens

STEP ACTION
1 From an xterm window: ssh ^ sadira Logs in secure to this workstation. You can login to a different workstation if directed.
2 From the same window: ssh ^ -l ^ bcpm2 ^ bcpm2 Logs in to BCPM and brings up task selection menu. From the menu, select the u option (user interface). When prompted for a login name, press enter (default option). The following windows will launch: Status Display, Command Line Interface, Graphical User Interface, Level Monitor

BCPM Command Line Interface Window Commands

COMMAND ACTION
setpower Runs a script on the BCPM to set the power levels in the channels.
timing Used to set up the BCPM in timing mode and start acquiring data.
monitor Sets up the BCPM (for search and voltage sampling modes) and acquires data without saving it to disk or tape.
takedata Used in search and voltage sampling modes to commence taking a stretch of search data to disk or tape.
abort Stops the BCPM without saving the last data sample to disk or tape.
stop Stops the BCPM and saves the last data sample to disk or tape.

GO (or GO_LITE)

STEP ACTION
NOTE Only one session of GO may be run at any time.
1 To initiate GO with all devices enter: GO (Launches GO with the main menu appearing)
2 To initiate GO with specific devices deselected enter: GO ^ T The GO device menu will appear. Deselect those devices not required.
NOTE If GO hangs while initiating the antenna, start it using this command: GO ^ F ^ 10

Launch CLEO Device Screens

STEP ACTION
1 From the Cleo Launch menu, launch the following application: Applicable Receiver, LO, IF Rack, Converter Rack
2 Launch additional applications if needed or required for the specific observing run.

BCPM GO Panel and Setup Scripts

STEP ACTION
NOTE The config tool has replaced this configuration application and the older setup scripts, though they may be desired by some observers. Do not run unless requested.
1 To start the BCPM GO Panel, from an xterm window enter: PSRGUI (launches the application)
2 To run a setup script, from an xterm window enter: cd ^ include (changes to the include directory); then enter: glish ^ -l ^ xxxx.g (substitute the "xxxx" with the applicable script name); Select the option number corresponding to the desired receiver; Select the BCPM (option 1); Enter r (run option). The BCPM should now be ready.

Checking IF Power

  • Receiver
    • Check LO power: 5v is optimal
    • Check noise source: Firing

  • LO
    • Confirm: LO set for correct signal path to receiver
    • Confirm: Correct rest frequency

  • IF Rack
    • Confirm: Correct signal path setup for receiver
    • Balance: IR rack
    • Check RF power: 1v is optimal

  • Converter Rack
    • Confirm: Routing to correct Converter Module (Rack A CM4 & 8)
    • Confirm: Correct LO2 frequency
    • Check RF power: Values normally well below 1v
Changed:
<
<

-- DavidRose - 01 Aug 2004

>
>

-- DavidRose - 17 May 2005


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.5 - 18 Jan 2005 - EricKnapp)
Changed:
<
<

depending on the observers desires. This procedure consists of only the basic tasks to be completed. The following guide shows the basic tasks that may be completed:

>
>

depending on the observers desires. The following guide shows the basic tasks that may be required:

Deleted:
<
<

  • Starting applications 

  • Running the setup script 

  • Checking IF power 

Changed:
<
<

Launch BCPM Screens    

>
>

BCPM Screens    

Changed:
<
<

Start GO

>
>

GO

Info 

GO does not tolerate mutiple iterations of itselfe. Do NOT start GO unless instructed to do so by the observer.

Changed:
<
<

Launch BCPM GO Panel

>
>

BCPM GO Panel

Info 

As of 18JAN05 most all setups are done using the config tool. Do not run this unless instructed to by the observer.

Added:
>
>

Info 

As of 18JAN05 most all setups are done using the config tool. Do not run this unless instructed to by the observer. Config scripts are no longer supported and may be partially non-functional.


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.4 - 11 Aug 2004 - DavidRose)
Changed:
<
<

Module (Rack A CM7 & 8)

>
>

Module (Rack A CM4 & 8)

Changed:
<
<

-- DavidRose - 02 Oct 2003

>
>

-- DavidRose - 01 Aug 2004


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.3 - 23 Oct 2003 - DavidRose)
Changed:
<
<

%META:TOPICPARENT{name="TemporaryGBTOpsArea"}%

>
>

%META:TOPICPARENT{name="TelescopeOperations"}%


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.2 - 13 Oct 2003 - DavidRose)
Changed:
<
<

workstation. You can login to a different workstation if directed.)

>
>

workstation. You can login to a different workstation if directed)

Changed:
<
<

BCPM and brings up task selection menu. 

>
>

BCPM and brings up task selection menu) 


 <<O>>  Difference Topic PulsarObservingWithTheBCPM (r1.1 - 02 Oct 2003 - DavidRose)
Added:
>
>

%META:TOPICINFO{author="DavidRose" date="1065123519" format="1.0" version="1.1"}% %META:TOPICPARENT{name="TemporaryGBTOpsArea"}%

TELESCOPE OPERATIONS


PULSAR OBSERVING WITH THE BCPM

General

The following are basic procedures used to prepare for pulsar observations using the BCPM.

Info 

Additional specific settings will be required depending on the observers desires. This procedure consists of only the basic tasks to be completed. The following guide shows the basic tasks that may be completed:

  • Starting applications 

  • Running the setup script 

  • Checking IF power 

The character " ^ " is used below to emphasize spaces between dialog elements.

Starting Applications

Launch BCPM Screens    

STEP

ACTION
1 From an xterm window:
  • ssh ^ sadira  (logs in secure to this workstation. You can login to a different workstation if directed.)
  • ssh ^ -l ^ bcpm2 ^ bcpm2  (logs in to BCPM and brings up task selection menu. 
  • From the task selection menu, select the u option (user interface) 
  • When prompted for a login name, press enter (default option)

The following windows will launch:

  • Status Display
  • Command Line Interface
  • Graphical User Interface
  • Level Monitor

BCPM Command Line Interface Window Commands

COMMAND

ACTION
setpower Runs a script on the BCPM to set the power levels in the channels.
timing Used to set up the BCPM in timing mode and start acquiring data.
monitor Sets up the BCPM (for search and voltage sampling modes) and acquires data without saving it to disk or tape.
takedata Used in search and voltage sampling modes to commence taking a stretch of search data to disk or tape.
abort Stops the BCPM without saving the last data sample to disk or tape.
stop Stops the BCPM and saves the last data sample to disk or tape.

Start GO

STEP

ACTION
1 To initiate GO with all devices enter:    GO  (Launches GO with the main menu appearing)
2 To initiate GO with specific devices deselected enter:    GO ^ T 

The GO device menu will appear. Deselect those devices not required.

NOTE If GO hangs up while initiating the antenna, start it using this command instead:    GO ^ F ^ 10 

Launch CLEO Device Screens

STEP

ACTION
1 From the Cleo Launch menu, launch the following application:
  • Applicable Receiver
  • LO
  • IF Rack
  • Converter Rack

Launch additional applications if needed or required for the specific observing run.

Launch BCPM GO Panel

STEP

ACTION
1 From an xterm window:    
  • PSRGUI (launches the BCPM GO Panel)

Running The Setup Script

STEP

ACTION
1 From an xterm window:
  • cd ^ include (changes to the include directory)
  • glish ^ -l ^ xxxx.g (substitute the "xxxx" with the applicable script name)
  • Select the option number corresponding to the desired receiver.
  • Select the BCPM (option 1)
  • Enter r (run option)

The BCPM should be ready now.   

Checking IF Power

STEP

ACTION
1 Cleo receiver:
  • Check LO power:  5v is optimal
  • Check noise source:  Firing  
2 Cleo LO
  • Confirm:  LO set for correct signal path to receiver
  • Confirm:  Correct rest frequency
3 Cleo IF Rack:
  • Confirm:  Correct signal path setup for receiver
  • Balance:   IR rack
  • Check RF power:  1v is optimal
4 Cleo Converter Rack:
  • Confirm:  Routing to correct Converter Module (Rack A CM7 & 8)
  • Confirm:  Correct LO2 frequency
  • Check RF power:  Values normally well below 1v

-- DavidRose - 02 Oct 2003


Topic PulsarObservingWithTheBCPM . { View | Diffs | r1.8 | > | r1.7 | > | r1.6 | More }
Revision r1.1 - 02 Oct 2003 - 19:38 GMT - DavidRose
Revision r1.8 - 06 Feb 2008 - 16:52 GMT - DavidRose
Content copyright © 1999-2007 by the contributing authors.
All material on this collaboration platform is the property of the contributing authors.