The current and short term plans for receiver repairs and installation as well as feed changes for Prime Focus receivers are indicated in the tables below. The status codes for the hardware include: I - installed and operational, R - installed but in repair state and not available, RL - in repair/upgrade state in the lab, D - in development, and S - in storage. Dates enclosed in round braces () are tentative dates only.
|
Last Updated on March 31, 2004.
|
GBT Receivers
|
| Gregorian | | PrimeFocus |
| Receiver | Status | | Receiver | Feed | Status |
| L (1.15 - 1.73 GHz) | I | | PF1 (0.29-0.92 GHz) | 800 MHz | I 03/09/04 |
| S (1.73 - 2.60 GHz) | I | | PF2 (0.91-1.23 GHz) | N/A | S |
| C (3.95 - 5.85 GHz) | I | | |
| X (8.00 - 10.1 GHz) | I | | |
| Ku (12.0 - 15.4 GHz) | I | | |
| K (18.0 - 26.5 GHz) | I | | |
| Ka (26.5 - 40.0 GHz) | D | | |
| Q (40.0 - 50.0 GHz) | I | | |
|
| Feed | From | To | Action |
| 600 MHz | (03/30/04) | (04/02/2004) | Install |
| 800 MHz | (04/13/04) | (04/16/2004) | Install |
| PF2 band | (04/27/04) | (04/30/2004) | Install for commissioning and proj checkout |
|
| Feed | From | To | Action |
| PF1 | (05/01/2004) | (05/15/2004) | In lab repairs |
| X band | (07/01/2004) | (08/15/2004) | Filter, poln switch |
|