NRAO Home  >  Green Bank  |  Wiki Topic:    GB > Projects > KaRxFitsSpec (r1.1 vs. r1.6)
   Changes | Index | Contents | Search | Statistics | Jump to Topic:
 <<O>>  Difference Topic KaRxFitsSpec (r1.6 - 23 Oct 2007 - AmyShelton)
Changed:
<
<

Ka band receiver FITS file specification

>
>

Ka band receiver FITS file specification

Changed:
<
<

--Brian Mason, 30jul04

>
>



Introduction


 <<O>>  Difference Topic KaRxFitsSpec (r1.5 - 17 Jul 2007 - KarenONeil)
Changed:
<
<

As indicated in this example, the name of the INSTRUME for the Ka band receiver should be appropriate given whatever the standard naming convention is-- probably "Rcvr26_40". Probably this should be the same as the name of the subdirectory where this FITS file is found.

>
>

As indicated in this example, the name of the INSTRUME for the Ka band receiver should be appropriate given whatever the standard naming convention is -- "Rcvr26_40". This should be the same as the name of the subdirectory where this FITS file is found.

Changed:
<
<

  • PHASSRC and CALSRC: these keywords will have string values which denote whether the origin of the phase or cal switching signals (respectively) were: the MCB crate (value 'MCB'), the CCB (value 'CCB'), the system-wide switching signal distribution (value 'EXT'). These parameters are controled by the boxes labeled "Phase Ctrl" and "Cal Ctrl" on the Ka band CLEO screen. we should verify that there aren't more possible values (like 'NONE'?) for these parameters, and if there are, support those also. . I will check into this when I return, or you could probably find out from looking at the Ka manager code or talking to Melinda or Amy in the meantime.
  • LCALTRAK and RCALTRAK: these keywords will have boolean values denoting whether the individual calibration noise diodes were tracking the CAL signal specified by CALSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "External Track" on the Ka band CLEO screen.
  • D1SRTRAK, S1SRTRAK, D2SRTRAK, and S2SRTRAK: these keywords will have boolean values which denote whether the four individual phase switches were tracking the Phase (beamswitch) signal specified by PHASSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "Sig/Ref Track" on the Ka band CLEO screen.
  • D1BIAS, S1BIAS, D2BIAS, and S2BIAS: these keywords will have boolean values which denote whether the four HEMTs (D1, S2, D2, S2) were on (T) or off (F). These parameters are controled by the boxes labeled "Bias" on the Ka band CLEO screen.
>
>

  • PHASSRC and CALSRC: these keywords will have a string value which denotes the origin of the phase [cal] switching signal. Options are: Local control (value "'LOCAL'), the MCB crate (value 'MCB'), the CCB (value 'Ccb'), the system-wide switching signal distribution (value 'EXT'), or the Zpectrometer (value 'ZPEC'). These parameters are controled by the boxes labeled "Phase Ctrl" and "Cal Ctrl" on the Ka band CLEO screen.
  • LCALTRAK and RCALTRAK: these keywords will have boolean values denoting whether the individual calibration noise diodes were tracking the CAL signal specified by CALSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "External Track" on the Ka band CLEO screen.
  • D1SRTRAK, S1SRTRAK, D2SRTRAK, and S2SRTRAK: these keywords will have boolean values which denote whether the four individual phase switches (D1, D1, D2, and S2) were tracking the Phase (beamswitch) signal specified by PHASSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "Sig/Ref Track" on the Ka band CLEO screen.
  • D1BIAS, S1BIAS, D2BIAS, and S2BIAS: these keywords will have boolean values which denote whether the four HEMTs (D1, S2, D2, S2) were on (T) or off (F). These parameters are controled by the boxes labeled "Bias" on the Ka band CLEO screen.
Changed:
<
<

  • D1BYSW, S1BYSW, D2BYSW, S2BYSW: these keywords indicate the state of the new hybrid bypass switches. A value of "T" indicates the switch is active, i.e the hybrid is being bypassed. Although four keywords exist, only D1BYSW and S1BYSW are implemented in the hardware at this date (Sep 06).
>
>

  • D1BYSW, S1BYSW, D2BYSW, S2BYSW: these keywords indicate the state of the new hybrid bypass switches. A value of "T" indicates the switch is active, i.e the hybrid is being bypassed. Although four keywords exist, only D1BYSW and S1BYSW are implemented in the hardware at this date (Sep 06).
Changed:
<
<

-- BrianMason - 30 Jul 2004

  • Marked up Ka band Rx CLEO screen:
>
>

Marked up Ka band Rx CLEO screen:


 <<O>>  Difference Topic KaRxFitsSpec (r1.4 - 22 Sep 2006 - JoeBrandt)
Added:
>
>

As of FITSVER 2.2:

  • D1BYSW, S1BYSW, D2BYSW, S2BYSW: these keywords indicate the state of the new hybrid bypass switches. A value of "T" indicates the switch is active, i.e the hybrid is being bypassed. Although four keywords exist, only D1BYSW and S1BYSW are implemented in the hardware at this date (Sep 06).

 <<O>>  Difference Topic KaRxFitsSpec (r1.3 - 21 Sep 2004 - BrianMason)
Added:
>
>

--Brian Mason, 30jul04

Changed:
<
<

The required keywords will be those explained in

>
>

The required keywords will be those explained in GBT Software Project note 4.3.2, "Device and Log FITS Files for the GBT", to be found at:

Changed:
<
<

To help clarify(?) the mappings I've marked up a screenshot of the Ka band CLEO screen and attached it below.

>
>

To help clarify the mappings I've marked up a screenshot of the Ka band CLEO screen and attached it below.


 <<O>>  Difference Topic KaRxFitsSpec (r1.2 - 30 Jul 2004 - BrianMason)
Deleted:
<
<

Changed:
<
<

  • PHASSRC and CALSRC: these keywords will have string values which denote whether the origin of the phase or cal switching signals (respectively) were: the MCB crate (value 'MCB'), the CCB (value 'CCB'), the system-wide switching signal distribution (value 'EXT'). These parameters are controled by the boxes labeled "Phase Ctrl" and "Cal Ctrl" on the Ka band CLEO screen.
>
>

  • PHASSRC and CALSRC: these keywords will have string values which denote whether the origin of the phase or cal switching signals (respectively) were: the MCB crate (value 'MCB'), the CCB (value 'CCB'), the system-wide switching signal distribution (value 'EXT'). These parameters are controled by the boxes labeled "Phase Ctrl" and "Cal Ctrl" on the Ka band CLEO screen. we should verify that there aren't more possible values (like 'NONE'?) for these parameters, and if there are, support those also. . I will check into this when I return, or you could probably find out from looking at the Ka manager code or talking to Melinda or Amy in the meantime.

 <<O>>  Difference Topic KaRxFitsSpec (r1.1 - 30 Jul 2004 - BrianMason)
Added:
>
>

%META:TOPICINFO{author="BrianMason" date="1091211540" format="1.0" version="1.1"}% %META:TOPICPARENT{name="KaBandReceiver"}%

Ka band receiver FITS file specification

The Ka band receiver will record one FITS file for every scan. This FITS file will be written in the directory named after the receiver which is also currently used by the measurements manager to write the calibration FITS file (which is only done once per observation, not once per scan). These two types of files will be distinguished by their contents. Since the calibration FITS file has a bogus date and time (date is the date of the lab calibration measurement provided by the engineers; times are all zeros) we are confident the files won't overwrite each other. The name of the receiver FITS file should be generated as per the current convention as to date and time (eg, 2004_07_06_04:23:12.fits).

Required keywords

The required keywords will be those explained in http://wwwlocal.gb.nrao.edu/GBT/MC/doc/dataproc/gbtFits/gbtFits/node2.html

The example given in this document (slightly modified here in the INSTRUME keyword) is:

SIMPLE  =                    T / file does conform to FITS standard
BITPIX  =                    8 / number of bits per data pixel
NAXIS   =                    0 / number of data axes
EXTEND  =                    T / FITS dataset may contain extensions
ORIGIN  = 'NRAO Green Bank'    /
INSTRUME= 'Rcvr26_40'       / device or program of origin
GBTMCVER= '3.3.0   '           / telescope control software release
FITSVER = '1.1     '           / FITS definition version for this device
DATEBLD = 'Thu Jun 21 18:46:25 GMT 2001' / time program was linked
SIMULATE=                    0 / Is the instrument in simulate mode?
DATE-OBS= '2001-11-17T15:54:13' / Manager parameter startTime
TIMESYS = 'UTC     '           / time scale specification for DATE-OBS
TELESCOP= 'NRAO_GBT'           / Green Bank Telescope (Robert C. Byrd 100m)
OBJECT  = '1950+34 '           / Manager parameter source
PROJID  = 'test    '           / Manager parameter projectId
OBSID   = 'map     '           / Manager parameter scanId
SCAN    =                  543 / Manager parameter scanNumber
 :
 :
(other application-specific keywords)
 :
 :
END

As indicated in this example, the name of the INSTRUME for the Ka band receiver should be appropriate given whatever the standard naming convention is-- probably "Rcvr26_40". Probably this should be the same as the name of the subdirectory where this FITS file is found.

Ka band receiver keywords

The Ka band receiver manager will, in addition, record the following keywords.

  • PHASSRC and CALSRC: these keywords will have string values which denote whether the origin of the phase or cal switching signals (respectively) were: the MCB crate (value 'MCB'), the CCB (value 'CCB'), the system-wide switching signal distribution (value 'EXT'). These parameters are controled by the boxes labeled "Phase Ctrl" and "Cal Ctrl" on the Ka band CLEO screen.
  • LCALTRAK and RCALTRAK: these keywords will have boolean values denoting whether the individual calibration noise diodes were tracking the CAL signal specified by CALSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "External Track" on the Ka band CLEO screen.
  • D1SRTRAK, S1SRTRAK, D2SRTRAK, and S2SRTRAK: these keywords will have boolean values which denote whether the four individual phase switches were tracking the Phase (beamswitch) signal specified by PHASSRC (value of TRUE=T) or not tracking it (value of FALSE=F). These parameters are controled by the boxes labeled "Sig/Ref Track" on the Ka band CLEO screen.
  • D1BIAS, S1BIAS, D2BIAS, and S2BIAS: these keywords will have boolean values which denote whether the four HEMTs (D1, S2, D2, S2) were on (T) or off (F). These parameters are controled by the boxes labeled "Bias" on the Ka band CLEO screen.

The values associated with these keywords should denote the parameter values at the start of the scan, which by assumption will be constant within a scan.

To help clarify(?) the mappings I've marked up a screenshot of the Ka band CLEO screen and attached it below.

Extensions

The Ka band receiver will have no extensions-- the header contains all the information that is needed.

-- BrianMason - 30 Jul 2004

  • Marked up Ka band Rx CLEO screen:
    karxcleo.jpg

%META:FILEATTACHMENT{name="karxcleo.jpg" attr="" comment="Marked up Ka band Rx CLEO screen" date="1091211241" path="karxcleo.jpg" size="400665" user="BrianMason" version="1.1"}%


Topic KaRxFitsSpec . { View | Diffs | r1.6 | > | r1.5 | > | r1.4 | More }
Revision r1.1 - 30 Jul 2004 - 18:19 GMT - BrianMason
Revision r1.6 - 23 Oct 2007 - 12:35 GMT - AmyShelton
Content copyright © 1999-2007 by the contributing authors.