Cryogenics-Receiver Mappings


Compressor-Receiver

Compressor Receiver 1 Receiver 2
1 PF1  
2 Rcvr40_50(Q)  
3 Rcvr4_6(C)  
4 Rcvr2_3(S)In lab Rcvr8-10(X)
5 Rcvr18_26(K) Rcvr26_40(Ka)
6 Rcvr12_18(Ku) Rcvr1_2(L)


Refrigerator Drive-Receiver

  Supply 1 Supply 2 Supply 3 Supply 4 Supply 5
Drive S1   -   - PF
Drive S2 - - Rcvr4_6 (C) Rcvr18_26(K) -
Drive S3   - Rcvr1_2 (L)   Rcvr40_50(Q)
Drive S4 - - - Rcvr12_18(Ku) -
Drive S5   - Rcvr8_10 (X) Rcvr2_3(S) Rcvr26_40 (Ka)


Updating the Motorrack Configuration File

The control state of the refrigerator power supplies is specified via a configuration file /home/gbt/etc/config/MotorRack.conf. To update the configuration the following steps should be followed:

MotorRack.conf File Format:

The following sections present example portions of the MotorRack.conf configuration file.

Manager Power-up State:

The following section controls the initial state of each sub-manager. If a power supply is removed, the corresponding manager should be set to the off state on power-up.

Warning and Fault Levels for Temp Sensors

This section specifies the temperatures at which messages will trigger. The location is specified by the numeric index. Locations are:

Example Entry:

Refrigerator Power Supply Control

The following section specifies the state of each power supply outputs. There are five supplies, (specified by the index 1..5) with each having five outputs (S1..S5).

Attachment: sort Action: Size: Date: Who: Comment:
cleomotor.gif action 27133 06 Jun 2006 - 15:59 JoeBrandt  

Topic CryoMapping . { Edit | Attach | Ref-By | Printable | Diffs | r1.19 | > | r1.18 | > | r1.17 | More }
Revision r1.19 - 02 Jul 2008 - 19:19 GMT - BobSimmons
Parents: WebHome > ElectronicsKnowledge
Content copyright © 1999-2007 by the contributing authors.
All material on this collaboration platform is the property of the contributing authors.