| STEP | ACTION |
|---|---|
| 1 | Take manual control by pressing the Halt button on the main console window. |
| 2 | Press the Service Position button. The antenna will move to position and set the gear reducer brakes. |
| 3 | Press the Idle button. Sets the stow brake and sets the hydraulics to bleed mode. |
| 4 | Personnel can now lockout the antenna servo system for maintenance actions as required. |
| STEP | ACTION | |
|---|---|---|
| 1 | Take manual control by pressing the Halt button on the main console window. | |
| 2 | Press the Stow button. The antenna will move to stow position and set the gear reducer brakes. | |
| 3 | Press the Idle button. Sets the stow brake and sets the hydraulics to bleed mode. | |
| 4 | Personnel can now lockout the antenna servo system for maintenance actions as required. | |
| STEP | ACTION |
|---|---|
| 1 | Take manual control by pressing the Halt button on the main console window. |
| 2 | On the main console, click on Commanded Position to bring up the control panel for manually moving the antenna. |
| 3 | Set rates, release brakes, and command RA and/or DEC moves only as the mechanics direct. |