TPAR 19 observing log

Weather : NOT great - can not see many stars

From 23:00 to 23:45 the telescope was below 15 degrees - baseplate warmed to >15K.  A full cycle had been completed at ~16:00 and the He4 and He3 fridges held.

To get Orion we decided not to complete a quick cycle.

00:00 - could start to bias detectors - address card did not work at first but started with a 1 minute power cycle.

Scans 1-5 - tests of scan to set focus offsets
Scan 6 - start scan
Scan 7 CAL 1.2V
Scan 8 blank
Scan 9,10,11,12,13 focus 0530+135
For some reason column 0 had bias set to 1000 - rebiased
Scan 14 - cal again 1.2V
Scan 15 - blank
Scan 16,17,18,19,20 focus [-12,-8,-4,0,4] 0530+135
     SCAN 18 WILL NOT READ
Scan 21,22 focus -2,+2
scan 23 quick daisy 0530+135 lfcy 0
Scans 24-28 Orion north box scans
Scans 29-33 Orion south box scans
     ****time offsets of 0.2 seconds are being found!!!!****
     1:35 WEATHER - no stars can be seen
Scan 34 CAL 1.2V on orion
     RELOCK - several detectors went out of lock
Scan 35 Blank on orion\
Scans 36,37,38,39,40 focus scans 0530+135 [-7,-4,-1,2,5]
      TO MARS
Scans 41,42,43,44,45 Focus scans on Mars [-7,-4,-1,2,5]
Scan 46 - CAL 1.2V  (BUT THERE SEEMS TO BE NO CAL)
Scan 47 - blank
Scan 48 in focus (-5mm) quick daisy
Scan 49 3'full daisy on center - aborted!!!
Scan 50,51,52,53,54  3'full daisy offset in az by 2 arcminute
Scan 55,56,57,58,59 repeat of above
Scan 60,61,62 subreflector daisy 2' offset in az lfcys of [-9,-5,-1]
Scan 63,64,65 subreflector daisy on axis lfcy of [-9,-5,-1]
Scan 66 CAL 1.2V just off Mars
Scan 67 Blank just off mars
     WEATHER - can see Orion
Scan 68 Start of noise vs elevation - tip 40 degrees to 70.8
Scan 69 Blank scan 60 seconds at 70.86 degrees
Scan 70 tip 71 to 60 degrees
Scan 71 blank @ 59.5 degrees
Scan 72 Tip 60 to 48 degrees 
Scan 73 blank at 48 degrees
Scan 74 Tip to 36.5 degrees
Scan 75 blank at 36.5 degrees
Scan 76 Tip to 30.2 degrees
Scan 77 blank at 30.2 degrees
Scan 78 Tip to 23.7 degrees
Scan 79 blank at 23.7 degrees
Scan 80 tip 23.7 degrees to 17.28
Scan 81 blank at 17.28 degrees    lfcy[ss+n_focus] = map.LFCY

Scan 82 - aborted telescope is way over.
     GO to 3C279 (1256-0547)
Scan 83-Aborted - Data has offset pointing
Scan 84,85,86,87 focus daisy on 3c279
Scan 88 Cal 1.2V
Scan 89 blank
     OOF on 3C279
Scan 90 OOF scan -14mm lfcy using new scan pattern (slower, smoother)
Scan 91 OOF scan -5mm lfcy
Scan 92 OOF scan +4mm lfcy
     USe lfcy-5 focus from this
     GOTO M87
Scans 93,94,95 box scan 2'x2'on M87
Scan 96 Cal 1.2V 
Scan 97 blank
Scans 98,99,100,101 point + focus on 3c279 [-12,-8,-4,0]
Scan 102,103,104 box scan (2'by 2') on M87
     GOTO M82
Scans 105,106,107,108 focus 0753+5352 best focus = -4mm
scans 109,110,111 box scans on M82
Scans 112 'Full' daisy, on M82 r=1' 
      Now arp220
Scans 113-118 focus scans on 1549+0237 (few Jy source)
Scan 119,120,121 box scans 2'x2' on arp220
     WEATHER - sky is clear (can see stars in most directions)
Scan 122, 123,124,125 focus daisy on 1549+0237
Poinintg changed to .178'in el and from +.03' to -0.033' in az , focus is at -5mm
Scan 126 CAL 1.2 V
Scan 127 Blank
Scan 128,129 focus daisys at -7mm,-3mm 
Scan 130 'full' daisy on arp220
Sacn 131,132,133 box map on arp220
Scan 134 'full' disy on arp220
Scan 135 'ful'daily on 1549+0237
Scan 136 Cal at 1.2V
Scan 137 blank

Fridge vibration tests
 - carry out at an elevation of 25 degrees
Scan 138 Cal at 1.2V - (array heater turned on for a few seconds)
Scan 139 Blank scan 2 minutes
Scan 140 2 minute blank scan L band off 1:36 and back on at 0.43
Scan 141 2 minute blank scan Q band off at 1:26 back on at 0.42
Scan 142 2 minute blank scan S band off at 1:40 back on 0.39
Scan 143 started by scan manager L,Q,S off 1:30? - 0.39
Scan 144 ka band on at 0:27
Scan 145 K & ku off 1:31 on 0.37
Scan 146 L,Q,S,ka,K (not x band) off at 1:22 back on 0.2
Scan 147 all on
     Weather - 7:15am very clear overhead. Fairly cold (-3.74C)

Switch to Ka and attempt to get some supporting data on Arp220 and
perhaps M82. We had some trouble with astrid -- plots not showing
up from peak scans -- did a bunch of them and restarted a couple
of times before things started to work (s.154)

Scans 148-161 - peak and focus
Scans 162-166 Nods on apr220
Scans 167,168 Ka band map

-- SimonDicker - 22 Jan 2008