NRAO Home  >  Green Bank  |  Wiki Topic:    GB > Projects > KaBandReceiver > KaRxFitsSpec
   Changes | Index | Contents | Search | Statistics | Jump to Topic:

Ka band receiver FITS file specification



Introduction

The Ka band receiver will record one FITS file for every scan. This FITS file will be written in the directory named after the receiver which is also currently used by the measurements manager to write the calibration FITS file (which is only done once per observation, not once per scan). These two types of files will be distinguished by their contents. Since the calibration FITS file has a bogus date and time (date is the date of the lab calibration measurement provided by the engineers; times are all zeros) we are confident the files won't overwrite each other. The name of the receiver FITS file should be generated as per the current convention as to date and time (eg, 2004_07_06_04:23:12.fits).

Required keywords

The required keywords will be those explained in GBT Software Project note 4.3.2, "Device and Log FITS Files for the GBT", to be found at: http://wwwlocal.gb.nrao.edu/GBT/MC/doc/dataproc/gbtFits/gbtFits/node2.html

The example given in this document (slightly modified here in the INSTRUME keyword) is:

SIMPLE  =                    T / file does conform to FITS standard
BITPIX  =                    8 / number of bits per data pixel
NAXIS   =                    0 / number of data axes
EXTEND  =                    T / FITS dataset may contain extensions
ORIGIN  = 'NRAO Green Bank'    /
INSTRUME= 'Rcvr26_40'       / device or program of origin
GBTMCVER= '3.3.0   '           / telescope control software release
FITSVER = '1.1     '           / FITS definition version for this device
DATEBLD = 'Thu Jun 21 18:46:25 GMT 2001' / time program was linked
SIMULATE=                    0 / Is the instrument in simulate mode?
DATE-OBS= '2001-11-17T15:54:13' / Manager parameter startTime
TIMESYS = 'UTC     '           / time scale specification for DATE-OBS
TELESCOP= 'NRAO_GBT'           / Green Bank Telescope (Robert C. Byrd 100m)
OBJECT  = '1950+34 '           / Manager parameter source
PROJID  = 'test    '           / Manager parameter projectId
OBSID   = 'map     '           / Manager parameter scanId
SCAN    =                  543 / Manager parameter scanNumber
 :
 :
(other application-specific keywords)
 :
 :
END

As indicated in this example, the name of the INSTRUME for the Ka band receiver should be appropriate given whatever the standard naming convention is -- "Rcvr26_40". This should be the same as the name of the subdirectory where this FITS file is found.

Ka band receiver keywords

The Ka band receiver manager will, in addition, record the following keywords.

As of FITSVER 2.2:

The values associated with these keywords should denote the parameter values at the start of the scan, which by assumption will be constant within a scan.

To help clarify the mappings I've marked up a screenshot of the Ka band CLEO screen and attached it below.

Extensions

The Ka band receiver will have no extensions-- the header contains all the information that is needed.

Marked up Ka band Rx CLEO screen:

karxcleo.jpg

Attachment: sort Action: Size: Date: Who: Comment:
karxcleo.jpg action 400665 30 Jul 2004 - 18:14 BrianMason Marked up Ka band Rx CLEO screen

Topic KaRxFitsSpec . { Edit | Attach | Ref-By | Printable | Diffs | r1.6 | > | r1.5 | > | r1.4 | More }
Revision r1.6 - 23 Oct 2007 - 12:35 GMT - AmyShelton
Parents: WebHome > KaBandReceiver
Content copyright © 1999-2007 by the contributing authors.
All material on this collaboration platform is the property of the contributing authors.