The ZSpectrometer is a new backend whic will undergo commissioning this fall. After commissioning it will become a facility backend. To facitliate both commissioning and observing with the instrument, the config tool should be modified to support it.

2. Background

This link provides information on the [ZSpectrometer Manager. See NRAO Zpectrometer Wiki for general information on the backend.

3. Requirements

WASP keyword type level unit description source Manager Parameter comments
chopfreq d C Hz Cal (noise diode) firing frequency   chopfreq Needs new name!
beclip# s C   Backend active channel range   bclip  
defcold s W   Cold type for tcold=-1   defcold  
defhot s W   Hot type for thot=-1   defhot  
diagout b W   Write diagnostic files   diagout We should probably use debugLevel for this since it is already part of the Manager.
exposure d C s Effective integration time   scanLength This is different - the is the actual time, not requests
object s H   source name   source  
obsid s H   scan number   scanNumber  
projid s H   Project identification   projectId  
tcaltype s W   Calibration algorithm   tcaltype  
tcold d W K Cold load temperature   tcold  
thot d W K Hot load temperature   thot  

This is a strawman proposal as to how the config tool keywords might mapped to ZSpectrometer Manager parameters.

Main.Melinda I have seen various names for the WASP programs linked on our web. What are the current "legal" names? The slides in wasp-slides-1.ps only describe 3 : tcal, totltpw and nobs. Yet other documentation lists the above programs.

MelindaMello Are these parameters set for all observing Programs or are they only required for some observing Programs?

MelindaMello I need valid ranges and default values for all config tool keywords. These are the startup defaults which may or may not be the defaults the config tool should use (if any). For example -1 as a default for exposure seems like a bad idea! beclip [1..9999) chopfreq = -1 defcold = 'sky' defhot = 'ambient' NOTE: are their illegal combinations of defcold and defhot? exposure = -1 tcaltype = 'vane' NOTE: tcaltype VANE, I know nothing about. tcold = 77 thot = -1 obsmode = 'undefined'

In addition the LO! must be removed from the ScanCoordinators?' device list for some if not all (?) configurations of the zspectromter?

4. Design

6. Deployment Checklist

What has to get done to integrate this completely into the system. This checklist must be completed before Cycle Integration Testing begins.

7. Test Plan

7.1 Internal Testing

7.2 Sponsor Testing


Signatures

APPROVED: I acknowledge that my request is fully contained in this MR, and if the SDD delivers exactly what I specified, I will be happy.

ACCEPTED: I acknowledge that I have validated the completed code according to the acceptance tests, and I am happy with the results.

Written DONE - MelindaMello - 02 Aug 2006
Checked  
Approved by Sponsor symbol - name - date
Approved by CCC symbol - name - date
Accepted/Delivered by Sponsor symbol - name - date

Symbols:


CCC Discussion Area

-- MelindaMello - 22 Aug 2006

Topic ModificationRequest1C606 . { Edit | Attach | Ref-By | Printable | Diffs | r1.1 | More }
Revision r1.1 - 22 Aug 2006 - 14:49 GMT - MelindaMello Content copyright © 1999-2007 by the contributing authors.
All material on this collaboration platform is the property of the contributing authors.